Warning: include(/home/quintpub/public_html/journals/prd/includes/code.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 2

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prd/includes/code.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 2
Interproximal Papilla Stability Around CAD/CAM and Stock Abutments in Anterior Regions: A 2-Year Prospective Multicenter Cohort Study
Warning: include(/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php) [function.include]: failed to open stream: No such file or directory in /home/quintpub/public_html/journals/prd/abstract.php on line 39

Warning: include() [function.include]: Failed opening '/home/quintpub/public_html/journals/prdincludes/05_update/javascript.php' for inclusion (include_path='.:/usr/lib/php:/usr/local/lib/php') in /home/quintpub/public_html/journals/prd/abstract.php on line 39
Follow Us      

LOGIN

   Official Journal of The Academy of Osseointegration

 
Share Page:
Back

Volume 37 , Issue 5
September/October 2017

Pages 657–665


Interproximal Papilla Stability Around CAD/CAM and Stock Abutments in Anterior Regions: A 2-Year Prospective Multicenter Cohort Study

Diego Lops, DDS, MSc, PhD/Andrea Parpaiola, DDS/Gianluca Paniz, DDS, PhD/Luca Sbricoli, DDS/Vanessa Ruiz Magaz, DDS, PhD/Alvise Cenzi Venezze, DDS/Eriberto Bressan, DDS/Edoardo Stellini, DDS


PMID: 28817129
DOI: 10.11607/prd.3184

The aim of this study was to compare the interproximal papilla stability of restorations supported by computer-aided design/computer-assisted manufacture (CAD/CAM) abutments to those supported by prefabricated stock abutments in anterior areas over a 2-year follow-up. Abutments were selected depending on implant inclination and thickness of buccal peri-implant soft tissues from the following: zirconia stock, titanium stock, zirconia CAD/CAM and titanium CAD/CAM. Differences between the height of the papilla tip were measured (REC). Results: REC values of titanium and zirconia CAD/CAM abutments were significantly lower than those of titanium and zirconia stock. The use of titanium and zirconia CAD/CAM abutments is related to better interproximal papillae stability.


Full Text PDF File | Order Article

 

 
Get Adobe Reader
Adobe Acrobat Reader is required to view PDF files. This is a free program available from the Adobe web site.
Follow the download directions on the Adobe web site to get your copy of Adobe Acrobat Reader.

 

© 2020 Quintessence Publishing Co, Inc

PRD Home
Current Issue
Ahead of Print
Archive
Author Guidelines
About
Submission Form
Submit
Reprints
Permission
Advertising
Quintessence Home
Terms of Use
Privacy Policy
About Us
Contact Us
Help